Simple Contact Wireless Transfer Unit WCP-LR16U
Simple Contact Wireless Transfer UnitWireless Transfer of Contacts Between Distant Facilities
Simple Contact Wireless Transfer Unit
WCP-LR16UAvailable in Canada / USA

WCP-LR16U is a contact wireless transfer unit with a simple configuration that is used in pairs. By simply connecting the WCP-LR16U to equipment, wireless transfer is possible up to 16 contacts between equipment approximately 300 m (328 yd) indoors and approximately 2,000 m (2,187 yd) in line of sight.
Possible wireless transfer up to
"uni-directional 16 contacts" and "bi-directional 8 contacts"
Possible wireless transfer up to approximately 300m (328 yd) indoors
and approximately 2,000 m (2,187 yd) in line of sight
Possible to use simultaneously up to 15 pairs of the unit within
the same communication area
Setting and installation are easy, and no wiring is required.
It can be used in various cases.
- Monitoring of abnormalities and operation status from production equipment
- Start and stop instructions between AGVs and stations
- Monitoring alarms from environmental measurement equipment
- Demand control of air conditioner outdoor units
- Monitoring the status of production robots
- Monitoring various liquids in storage tanks and pipelines in plants, etc.
CASE 1
Monitoring of abnormalities and
operation status from production equipment

Production equipment
Casting process,
pressing process, etc.

Equipment shutdown
information, etc.

Control panel
CASE 2
Start and stop instructions
between AGVs and stations

AGV

AGV position and
stop information, etc.

Station
CASE 3
Monitoring alarms from environmental
measurement equipment

Oxygen concentration andgas detector
(with alarm)

Oxygen concentration andgas detector
alarms, etc.

Transferring alarms to
distant locations
CASE 4
Demand control of air conditioner outdoor units

Outdoor unit

Power control signals, etc.

High-voltage power
receiving equipment
CASE 5
Monitoring the status of production robots

Production robot

Robot abnormality
information, etc.

Control panel
CASE 6
Monitoring various liquids in storage
tanks and pipelines in plants

Storage tank

Float switch,
level switch
information,
etc.

Monitoring panel
control panel
Features and Characteristics
Possible wireless transfer up to
"uni-directional 16 contacts" and "bi-directional 8 contacts"
Possible wireless transfer up to
"uni-directional 16 contacts" and "bi-directional 8 contacts"


Equipment

Uni-directional
16 Contacts


Equipment

8 Contact Outputs

Equipment

Bi-directional
8 Contacts

8 Contact Inputs

Equipment
Possible wireless transfer up to approximately 300 m (328 yd) indoors
and approximately 2,000 m (2,187 yd) in line of sight
In standard mode, "communication distance of approximately 300 m (328 yd) indoors"
and "response time of 250 ms". In long-range mode, it can be extended to
"communication distance of approximately 2,000 m (2,187 yd) in line of sight".
- Indoors
- Standard Mode

Communication distance of approximately
300 m (328 yd) indoors / 1,000 m (1,094 yd) in line of sight

Response Time250 ms
- In clear line of
sight locations - Long-range Mode

Communication distance of approximately
300 m (328 yd) indoors / 2,000 m (2,187 yd) in line of sight

Response Time1,000 ms
Response time and communication distance may vary depending on the usage conditions.
Possible to use simultaneously up to 15 pairs of the
unit within the same communication area
By incorporating in-house developed small LoRa wireless module
(920 MHz band wireless communication),
we have achieved simultaneous usage of up to 15 pairs of the unit.
- By setting a unique channel for each pair of the unit from the available 15 channels, it becomes possible to have simultaneous usage of 15 pairs of the unit within the same communication area.
- By conducting communication with the paired unit only during "input signal change" and "communication status monitoring", we minimize communication errors caused by radio interference as much as possible.
- If a communication error occurs, the unit will automatically resend the signal during communication status monitoring to ensure reliable delivery to the paired unit.
Note: If communication errors occur despite having a good communication environment, please try the following: "Change the channel," "Increase the distance between WCP-LR16U units," and "Set non-adjacent channels to each WCP-LR16U installed in close proximity".
Note: The number of available pairs of the unit remains the same for both standard mode and long-range mode.
Note: The number of available pairs of the unit remains the same even if the pairs set in standard mode and the pairs set in long-range mode are mixed within the same communication area.
Communication Environment
Checking Function
By conducting continuous communication with the paired unit, the communication environment is displayed using LEDs in 5 levels (excellent, good, fair, poor, very poor). You can use the check result of the communication environment as a reference to determine the installation location of WCP-LR16U.
Communication Status
Monitoring Function
WCP-LR16U conducts communication with the paired unit at intervals of the set time (10 s / 60 s) and performs LED lighting and error output when communication errors occur.
Both Voltage and Non-voltage
Contact Compatible
When using the WCP-LR16U terminals in the input setting, you can switch between voltage contact input and non-voltage contact input by opening and shorting the A and B terminals.
Opening Terminals A and B
for Voltage Contact Input
(Applied voltage DC24V)
Shortening Terminals
A and B for
Non-voltage Contact Input
Built-in
Small LoRa
Wireless Module
Developed
In-house
Specifications
Item | Specifications |
Frequency Band | 905.0MHz-927.4MHz (15 channels) LoRa Modulation |
Communication | Bi-directional Communication (Simplex) |
Available Countries | Canada / USA |
Input/Output |
16 Input / Output for Contact 1 Terminal Pair for Switching Between Voltage / Non-voltage Contact Input, 1 ERR Output |
Display |
1 Green LED for power indication, 1 Red LED for Communication Error Indication 1 Red / Green LED for Wireless Communication Monitoring 1 Red / Green LED for Monitoring I / O 1-8 1 Red / Green LED for Monitoring I / O 9-16 |
Power Source | DC 24 V ±10% (21.6 - 26.4 V) |
Current Consumption | 120 mA or less (at DC 24 V input) |
Operating Environment | Temperature: -10 to 60°C, Humidity: Up to 85% (non-condensing) |
External Dimensions (W x H x D) |
156 x 25 x 110 mm (6.1 x 1.0 x 4.3") (excluding protrusions) |
Weight | Approximately 440 g (15.5 oz) (including antenna) |
Antenna | Dipole Antenna |
Accessory | Dipole Antenna |
Catalogs
Related products
Please feel free to contact us regarding product inquiries, opinions, or requests.
Contact Us via Email